DINEC SC SERIES
Functions: | |||||
- Eliminates the hazards associated with storage and handling of gas chlorine. | |||||
- Eliminates the high cost for purchasing of commercial or industrial bleach. | |||||
- Eliminates the cost for storage and transportation of gas chlorine cylinders or bulky industrial bleach. | |||||
- Produces low strength solution of sodium hypochlorite at a safe way and the system is operating on demand. | |||||
Applications: | |||||
- Seawater Cooling System | |||||
- Seawater Toilet Flushing System | |||||
- Power Plants | |||||
- Waste Water Treatment System | |||||
- Refineries | |||||
- Petrochemical Plants |
Features: | |||||
Clear Cell Cover | : Allows the operators to know cell internal condition | ||||
Once Through Design | : Eliminate the current efficiency losses associated with recycle operation. | ||||
Dimensionally Stable Anodes | : Remains stable performance under harsh seawater and sodium hypochlorite condition. | ||||
Competitive Price | : Major parts imported from USA together with local assembling in Hong Kong. | ||||
Experience & Support | : Over 10-year experience and 50 job references in Hong Kong. | ||||
Minimal Power Consumption | : Hastelloy-C Cathodes is used to lower the power consumption by 10% as compared to that of titanium cathode | ||||
Specification: | |||||
Type of Electrode | : Plate Type | ||||
Cell Cover Material | : Clear Acrylic | ||||
Cell Body | : Machined PVC | ||||
Anode Material | : Titanium | ||||
Cathode Material | : Hastelloy-C | ||||
Anode Coating Material | : DINEC precious metal oxide coating | ||||
Wetted Hardware Material | : Titanium | ||||
Power Supply | : 380V / 50Hz / 3P | ||||
Model Description: | |||||
Model |
Equivalent Chlorine Capacity |
DC Volt / Ampere Requirement |
Seawater Flow Rate (M3/hr) |
Hydrogen Production Rate (SCFM) |
|
(lbs/day) |
(kg/day) |
||||
DINEC-SC-30/6P |
30 |
13.6 |
27V/100A |
4.5-9.0 |
0.1 |
DINEC-SC-60/6P |
60 |
27.7 |
27V/185A |
4.5-9.0 |
0.2 |
DINEC-SC-75/1P |
75 |
34.1 |
4.5V/1375A |
6.0-12.0 |
0.3 |
DINEC-SC-90/6P |
90 |
40.9 |
27V/280A |
6.0-12.0 |
0.3 |
DINEC-SC-120/6P |
120 |
54.4 |
27V/365A |
7.0-14.0 |
0.4 |
DINEC-SC-150/6P |
150 |
68.1 |
27V/460A |
7.0-14.0 |
0.5 |
DINEC-SC-150/1P |
150 |
68.1 |
4.5V/2750A |
7.0-14.0 |
0.5 |
DINEC-SC-180/6P |
180 |
81.8 |
27V/550A |
10.0-20.0 |
0.6 |
DINEC-SC-240/6P |
240 |
108.9 |
27V/730A |
13.5-27.0 |
0.8 |
DINEC-SC-300/3P |
300 |
136.1 |
13.5V/1800A |
13.5-27.0 |
1.1 |
DINEC-SC-320/6P |
320 |
145.2 |
27V/960A |
13.5-27.0 |
1.1 |
DINEC-SC-330/1P |
330 |
149.7 |
4.5V/6050A |
13.5-27.0 |
1.2 |
DINEC-SC-360/3P |
360 |
163.3 |
13.5V/2150A |
17.0-34.0 |
1.3 |
DINEC-SC-400/1P |
400 |
181.5 |
4.5V/7200A |
17.0-34.0 |
1.4 |
Max. operating pressure: 3 bars | |||||
Pressure drop: less than 0.2 bar (cell only) | |||||
Recommended Inlet / outlet pipe size: 2" (standard), 3" (optional) |